1. Buried Poly Ethylene (PE) pipe gas lines shall be 18” below finish grade or in an approved recessed channel with
14 gauge insulated tracer wire; Galvanized malleable iron, galvanized wrought iron, or galvanized steel, are
prohibited materials for use underground. TESTING: TEST PRESSURE SHALL BE 3lbs FOR 10
MINUTES.
2. Gas lines 6” or more above finish grade may be of Schedule 40 iron pipes without wrapping.
3. Piping installed above ground shall be securely supported and located where it will be protected from physical
damage. (Sec. 1211.1 U. P. C.)
4. Anti-entrapment type drain covers required per ASME/ANSI Standard A 112.19.8.
5. P-traps are required for all pools and spas.
6. Swimming pools or spas shall have at least two circulation drains per pump that shall be hydraulically balanced
and symmetrically plumbed through one or more “T” fitting, and that are separated by a distance of at least three
feet in any dimension between the drains.
7. Gas shutoff valve to be within 3 ft. of equipment are required for PE pipe. (Sec. 1210 U.P.C.)
8. Equipment venting to be a minimum of 4 ft. from building openings (Sec. 806.7 U.M.C.) and 4 feet from the
property line. (Sec. 416.6 Uniform Swimming Pool Code)
9. Non metallic electrical conduit shall be 18” below finish grade (P.V.C.) and 6” when below concrete and bonded
per Art. 680 N.E.C. (See table 300-5 for more information)
10. Hydrostatic relief valve is required for all pools and spas unless a soils report states otherwise.

b. Exception No. 2: Where space limitations prevent wiring from being muted 5 feet or more from the pool
such wiring shall be permitted where installed in rigid metal conduit, intermediate metal conduit or a nonmetallic
raceway system. All metal conduits shall be corrosion-resistant and suitable for the location. The
minimum burial depth shall be as follows:
Wiring Method Minimum Burial (Inches)
Rigid Metal Conduit 6
Intermediate Metal Conduit 6
Rigid Nonmetallic Conduit Approved for Direct
Burial without Concrete Encasement 18
Other Approved Raceways* 18
13. Underwater lighting fixtures shall be per Article 680-20 N.E.C.
14. Fencing shall be a minimum of 5 feet high with 4 inches maximum between vertical members, and 2 inches
maximum between horizontal members. Bottom of fence to be within 2 inches of firm soil or 4 inches to pavement.
A self-closing and self-latching gate, swinging away from the pool, with the latch at a minimum of 5 feet
above grade. A 48” vertical non climbable portion in fence is required.
15. Pool and spa lights to be G.F.I. protected.
16. A convenience outlet shall be provided no closer than 10’ and no more than 20 feet from water’s edge and shall be
G.F.I. protected (Per Nec 680-6).
17. Hose bibs must have anti siphon.
18. Paint all exposed ABS and PVC with a water base synthetic Lucite paint unless piping is labeled UV resistant.
19. Handrail is required for two or more steps leading to a slide. If over 30” in height then guardrails are required. If
there is a permanent barrier, then this requirement can be omitted at the inspector’s discretion.
20. Swimming pool heating system must contain the following measures mandated by the State Energy Regulations:

Accidental deposits shall be swept up immediately and may not be washed down by rain or other
means.
7. Any slopes with disturbed soils or removed vegetation shall be stabilized to inhibit erosion by wind
and water.
8. Stormwater pollution prevention devices and/or practices shall be modified as needed as the project
progresses to ensure effectiveness.
Energy Mandatory Requirements for Pool and Spa Heating Systems and Equipment
1. Certification by Manufacturers.
c. Instructions. A permanent, easily readable, and weatherproof plate or card that gives instruction for
CITY OF LAKE FOREST 25550 COMMERCENTRE DRIVE LAKE FOREST, CA 92630 • (949) 461-3470
g. Pilot light. No pilot light.
2. Installation. Any pool or spa heating system or equipment shall be installed with all of the